Zodiac Jandy iAquaLink 2.0 Wireless Network Pool Control Interface Sys. See Section 6.3, Step 2 of the owner's manual. 2023 Leslies Poolmart Inc. Were sorry we missed you; we look forward to assisting you soon. Jandy makes the Purelink Power Center that combines the Aqualink and Aquapure controls in one cabinet. High salt concentration above 4.0 gpl may damage the power center. Had to call a pool guy. Jandy AquaPure ClorMatic System Parts Metal Controller Here's another item of interest from p 877: IMPORTANT NOTICE NO WARRANTY if purchased online. 1 - Mounting Bracket, User Interface, APUREM. If chlorine output at lowest setting is still excessive then the salt water chlorinator system is oversized for the pool. Water conditioning salt pellets take longer to dissolve. Wichita Falls, TX. When the proper reading is reached press the Temperature button within 5 seconds to store it in memory. Clean if necessary. Where to buy Jandy AquaPure Power Center. If still too low, Super Chlorinate with outside source. Release the button after the 3rd beep. Jandy APUREM AquaPure Salt Generator Power Center, Brand new returned unit - Never installed just opened, Create a Saltwater Oasis in Your Backyard, Automatic self-cleaning feature ensures consistent operation and extended lifespan of the cell, Exclusive Tri-Sensor technology provides reliable electronic water flow detection to sustain maximum performance, even at very low flow rates, Digital salinity read-out for accurate salt-level indication, Flow, temperature and status readings provide instant feedback on the current operation, When combined with PureLink power centers, AquaLink and AquaPure work together for the ultimate in pool sanitizing and remote operation convenience, Seamless communication with AquaLink Control systems enables easy monitoring of salt levels and convenient, precise sanitizer output settings, Note: The salt cells are sold separately If there's a little adapter card between the old sensor cord and the circuit board, remove the adapter card. 21. The 700 cell has half the number of plates as the 1400 cell. The Jandy AquaPure Power Pack uses a process known as electrolysis to produce sodium hypochlorite (liquid chlorine) from a low concentration of salt added to the pool water. Regular Price: $212.61. Ensure that the flow/temp/salinity sensor is installed according to Section 3, Figure 11 of the owner's manual. contain additives. This corrosion increases the resistance of the connection and generates a lot of heat due to the high current of 6 to 8 amps. Sitemap | >PoolAndSpaPartsDepot.com is Open for Business! I bought one of these units from another vendor three years ago. Brief content visible, double tap to read full content. Our heavy-duty AquaPure salt chlorine generators have been the industry benchmark for years. If burnt connector contact authorized service representative. You can find instructions fore replacing and calibrating the tri-sensor in the AquaPure and PureLink Tri-Sensor Adapter Installation Kit Manual. Press and hold the test buttons marked salinity and R-temp. The TRI sensor only pertains to the swg. A 121 error can occur for a number of different reasons: dirty cell, damaged cell, bad cell cable, low salt level, cell wearing out due to age, or damaged power supply. 3 gpl is 3,000 ppm. Find inspiration for your home and garden. This is related to the serial com connections that are used. The systems are comprised of the following components: Arrived sooner than promised. Jandy Zodiac R0468501 Aqualink RS8 P&S Power Center Board . They can tell which ones are bad by the serial number. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. cargsl; Jul 19, 2022; Salt Water Chlorine Generators (SWG) Replies 10 They are built of a rugged glass-filled polypropelene material, have standard Jandy unions, and are NSF listed for your commercial application. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. The flow portion of the Flow/Temp/Salinity Sensor is a backup device only. You are using an out of date browser. In the case of a salt water chlorinator, the salt may damage the stone along the water line over time (crystallization). Please consider. If its 02110A10 or 01220A15, you use program A, otherwise you use program B on the in-line module on the trisensor cord. Item No. IS this the complete system? Why You Should Only Work With A Qualified Professional. Then the Aquapure system will be connected to your Aqualink system. Being relatively adept, I chose to install this myself. So the rating is 4 Stars. . See Section 6 of the owner's manual, User Maintenance Instructions. We are a registered 501(c)3 non-profit that is funded by user donations. If there is still a large amount of bromide in your pool, we recommend that you wait for it to dissipate. Free Shipping and more for Pool Perks members. (567 gm/24 Hr.). This applies to the Jandy AquaPure and the Nature2 FusionSoft as they are sister products. Be the first to review this product! When the cell needs replacement you should replace the cell, tri sensor, and power cord. Looks like your current store isn't near your delivery area. This issue is with the trisensor, which is a separate part that installs in the cell. We paired it with the APUREM. This may be necessary after heavy rains, backwashing and refilling, excessive splash out, etc. The only difference is the new part has a ground wire that was attached to the common ground.[15]. Register product at Jandy.com/registration. The PureLink DC Cord is Jandy P/N R0402800. JavaScript is disabled. Do I still need to use granular chlorine with my Salt water chlorinator? Currently, Jandy has part R0481400 which is the round transformer. Do I have to add salt every month with a salt water chlorinator? AquaPure Electronic Salt Water Chlorinator & PureLink Water Purification System Power Center & Cell Kit Installation & Operation Manual. AquaPure Salt Water Pool System - Jandy Remove and clean flow/temp/salinity sensor and reinstall. Either a short wait or a reboot resolve this. Easy to install and use. Check Cell studs for same. I am concerned that this will affect Freeze Protect mode this winter. See Section 5 of the owner's manual, Operating Instructions. The AquaPure system offers two cells that can generate different maximum amounts of chlorine in a 24 hour period. The Jandy AquaPure salt-water chlorine purifying systems use salt water to deliver high-performance water purification with uncompromised performance, reliability and hydraulic efficiency. There are beads at the bottom of my pool, what does it mean? BigCommerce Premium Themes by PSDCenter. Reviewed in the United States on December 6, 2014. Product information Feedback Would you like to tell us about a lower price? This action maintains the cell. Jandy AquaPure Control Center Parts |6 parts Frequently Purchased AquaPure Sanitizer Bottom Control Box Decal - R0404400 6 in stock $65.70 Add To Cart AquaPure Transformer - 115/230 Volts - R0481400 12 in stock $434.61 Add To Cart Control Box Cover, Pure1400 - R0403200 Allow 7-10 Days to Ship $185.91 Add To Cart Pure700 Control Box Cover - R0403100 The Jandy AquaPure system consists of a AquaPure Power Center or PureLink Power Centers and either a PURE700 cell or a PURE1400 cell. You can remove the two screws holding down the plate over the prongs and check the base of the prongs. Tri-Sensor R-kits will ship first, beginning with date code 10/6/14. Remove obstruction and/or clean cell. Jandy AquaPure Power Pack-APUREM - Pool Cleaning Parts WARNING - Zodiac Pool Systems Apple is not a participant or sponsor of this promotion. You will also find the cell sold alone at a lower price then the kit and it is tempting to buy only the cell. Even the High Voltage side wires were color coded identically. Recommend strongly. Red goes to green and blue goes to black/white. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115/230VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. The air temp went up. Field switchable to power all PureLink, ClorMatic and Nature2 Fusion Soft cell kits, LCD monitoring of chlorine production, cell modes, salinity, temperature, water flow and diagnostics. ORP / Freeze Control Unit 3 . Air, pool water, and SWG pool water. Get 1 point for every $1 spent. 120 is low current. See Section 4.5 of the owner's manual. Rely on its sturdy design and simple features to create your saltwater oasis. No instructions contained w/unit. Turn power to unit off and back on (Cycle Power). There was a problem adding this item to Cart. ORP / Freeze Control Unit 3 . The three pins go inside and connect to the plates. On the other hand if the readings are different then it indicates that there is a problem with the board. All other forms of chlorine (tablets, powder, liquid, etc.) The prongs are sealed by O-rings and a compression plate held down by two screws. Find a Dealer AquaPure Downloads Document ID SL5801CE Please try again later. The LCD should read 2.8 gpl*. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. Check that ribbon cable is fully inserted into connector. Jandy AquaPure Control Center Replacement Parts - Poolweb We made the decision to go to a salt water pool system. That is NOT what you have. When a FREEZE CONTROLLER is used on pump equipment and the chlorinator is run through the winter, turn the CHLORINE PRODUCTION down to 10 - 20%. 96. It is usually located underneath your Aqualink cabinet. You can buy this product once, or subscribe to have this product delivered to you as frequently as you wish. So it looks like it is good, but the water temp sensor is bad. It looks like WhatsApp is not installed on your phone. It's cheaper to go with another salt Unit came with panel knocked out and the circuit board was bad. After installing began to flash code of 181 & 172. If more chlorine is needed, activating the Boost mode will override this cold water feature allowing chlorine production for 24 hours of operation. Jandy Zodiac AquaPure PLC1400 PLC 1400 Saltwater Cell Kit AQUA PURE 352 8 offers from $1,209.92 Product Description This control box cover is designed to use with Zodiac AquaPure plastic control center model APURE700. You need to determine the correct Revisio, Q: The preferred salt is an evaporated, granulated, food quality, non-iodized salt. You have 3 temp sensors. Jandy - Power Center Transformer for AquaLink RS and AquaPure - Leslie's $1,079.00. ORP / External Control Interface 2. See Section 5, Operating Instructions of the owner's manual. A separate communication will follow . Look for heavy corrosion at both ends. Warning: shortening the polarity inversion time can wear the electrodes more than usual. The item you are trying to purchase is currently out of stock.Please enter your name, email, and phone number below. We will contact you as soon as this product is available. Is there only 1 water temperature sensor? The AquaPure has a 3 hour polarity cycle time (3 hours one polarity, 3 hours reverse polarity). Porto Seguro Cultural Center / Yuri Vital | ArchDaily Polarity will change every 3 hours. 2023 Zodiac Pool Systems LLC - All rights reserved. Test the salt level with a K-1766 Taylor Salt Test. The cell cannot be repaired even though the plates may have life left in them. Your question might be answered by sellers, manufacturers, or customers who bought this product. See Section 6.4 of the owner's manual. Rely on its sturdy design and simple features to create your saltwater oasis. Below 51F (11C), chlorine production is not permitted; operating the chlorinator in cold water might result in over-chlorinated pool water. PLC1400 (Cell Kit), Dolphin Above Ground Robotic Pool Cleaners, Dolphin Residential Robotic Pool Cleaners, Solar Cover Blankets - Above Ground Pools, Utility Company Rebates for Pool Equipment, Kreepy Krauly Pool Cleaners Above Ground Pools, Kreepy Krauly Pool Cleaners Inground Ground Pools, Polaris Pool Cleaners - Above Ground Pools, Pentair Above Ground Pool and Spa Pool Heaters, Pentair Master Temp Inground Pool and Spa Heaters, Raypak Pool and Spa Heaters Gas and Propane, Hayward Commercial Thermoplastic Pump HCP Series, Hayward DEP 500 Series Pleated Element D.E. If the readings are correct then the board is O.K. Broadcast or spread the salt into the outer perimeter of the pool, or into the shallow end of the pool for quick and even distribution. Find many great new & used options and get the best deals for Jandy Aquapure Clormatic III Front Panel Control Board Psd306-01 Apure1400 at the best online prices at eBay! The only hiccup we get, is an occasional communication error. Amazon.com: Zodiac R0403200 Control Box Cover Replacement for Zodiac AquaPure APURE1400 Plastic Control Center : Patio, Lawn & Garden . We evaluated 6535 medical consults of intoxication cases involving prescription and over-the-counter drugs in 2001. Press and hold the test buttons marked salinity and R-temp. Would recommend it to anyone needing a replacement or installinf for the first time. Note: The salinity or salt level should always be tested before salt is added to the pool. To Enter Boost Mode Press and Hold Temperature Button 10 Seconds, Here is an excerpt from page 423 (892)[6] of their 2019 catalog:[7], "This Jandy Limited Warranty does not apply to Jandy branded products purchased through the Internet or other e-commerce platforms, with the exception of Jandy branded valves, parts, and accessories. Had to down load from another site. Turn on the chlorinator or increase the chlorine production percentage. I'm upgrading my old AquaLink RS board to iAquaLink (with the IQ20-RS kit) and want to add an AquaPure 1400 salt generator. Salt level may decrease after a heavy rain, backwashing, refilling, draining or excessive splash out. Add salt as described in Section 4.7 of the owner's manual. Salt should be added to the pool when necessary. If the chlorinator is the correct size, then it's sufficient to sanitize the pool without adding granular chlorine. The PureLink Power Centers combine all the features of the AquaLink Power Centers and AquaPure water purification electronics in one box. All other firmware uses program B on the trisensor inline module. Thanks for identifying the water temperature sensor that will also have to be replaced. Zodiac / Jandy R0476400 Replacement Sensor Kit for AquaPure PLC700 / PLC1400. urban-think tank: groto community center in so paulo - Designboom 2) Order your Power Center. If one of them is rotted away, it's time for a new cell and cord. Help others learn more about this product by uploading a video! While still holding the two front board test buttons press the Pool Temperature key (D). No Flow indicator stays on continuously. Search in reviews, Q&A. The audible alarm is described on page 34 of the Jandy Pro Series AquaPure/PureLink Power Center and Cell Kit | Installation and Operation Manual.[4]. How does Aqualink RS Manage Solar and Gas Heating, Jandy IAqualink WiFi module with PDA Remote, iAqualink freeze protection - two specific questions, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. AquaPure Guide d'installation et mode d'emploi. In fairness to Zodiac/Jandy, they feel that a pool professional should do this. We have never winterized before. The arrow points to the water temperature sensor. Includes: 1 - Power Interface Board Assembly. It uses 240V and 50/60hz Export. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. If the ladder is bonded properly to the rest of the pool equipment, corrosion will be minimal. * Pricing, promotions and availability may vary by location and at lesliespool.com. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. Water conditioning salt pellets are compressed forms of evaporated salt and may be used. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. Super Chlorinate Pool. Jandy Aquapure Control Center | eBay Scale formation on pool equipment. Very happy with seller. Disconnect the flow salinity temp sensor from the board. Would buy again from them. They are sold as a kit.[2]. A common reason for the cell failing and getting error codes 120, 121 or 123 is one or more of the pins corroding and separating from its plate. Zodiac Jandy AquaPure Salt Cell Flow & Salinity Sensor |R0452500 The water balance will be less threatened, because only pure chlorine is added to the water. You can remove your cell for winter and install the dummy cell. The basic Jandy Aqualink RS System involves FIVE key elements: 1) Order your System Level. If the cell is old, just get the PLC1400 kit. Full content visible, double tap to read brief content. Winterize your pool. The percentage setting will control how much the cell runs during the production cycle.[5]. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. More Details. Salt only needs to be added when necessary. Jandy Aqualink RS : Swimming Pool Automation | Pool Supply Unlimited FREE delivery Feb 16 - 21 . The Jandy AquaPure APUREM salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. The aquapure power center is an electrical panel that is installed at the equipment pad. In the event no such state or local requirement exists, the installer and maintainer must be a professional with sufficient experience in pool equipment installation and maintenance.". The Jandy AquaPure APUREM salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. After installing began to flash code of 181 & 172. In preparation, I had upgraded our controller to the latest release of hardware and software, so I was familiar with most of the circuitry involved. The Flow & Salinity Sensor is Jandy P/N R0452500. JANDY AQUAPURE PLASTIC CONTROL CENTER, MODELS 700 & 1400 JANDY AQUAPURE | CONTROL BOX, PURE1400 | R0403000 Categories POOL PARTS SPA PARTS CHEMICAL FEEDER CLEANERS FILTERS FILTER ELEMENTS FILTER VALVES FITTINGS & UNIONS HEATERS LIGHTS PILLOW PLEATCO PLUMBING VALVES PUMPS SKIMMERS SPA AIR BLOWERS SPA FITTINGS SPA PACK CONTROL COMPONENTS Jandy Aquapure Clormatic III Front Panel Control Board Psd306-01 - eBay Is it possible to use salt water chlorination when the pool liner is in natural stone? Methods: A cross-sectional observational study was performed in the Intoxication Control Center of the Sao Paulo City Hospital. Also look inside the cell at the cord end. Cell trisensor senses temperature, salinity and flow. (Cycle Power). What is polarity inversion on a salt water chlorinator? 2023 Zodiac Pool Systems LLC - All rights reserved. The control center is connected with the pool circulation pump electrical source so that the electrolytic cell can only operate when the pool pump is on. The cartridge must be replaced. This site is protected by reCAPTCHA and the Google. Increase the system operating time per day. Add To Cart. We are a registered 501(c)3 non-profit that is funded by user donations. These clowns should join the Not reliable at all and have had problems starting about 1 month after installation. Boost 24 Hour 100% Chlorine Production Cycle. Jandy AquaPure 1400 Chlorine Generator | DSP - Discount Salt Pool The PDA uses the pool's temperature sensor. Free shipping for many products! Balance the water to recommended levels in Section 4.5 of the owner's manual. Jul 7, 2021. While still pressing the test buttons press the Salinity key (C) on the front cover of the unit. Had to call a pool guy. Report PoolGate Gold Supporter TFP Guide Jun 7, 2017 7,748 Damascus, MD Pool Size 29000 Jandy switched to a 3-port cell design to aid in cleaning and plumbing flexibility and no longer makes 2-port cells. The controller will periodically change the direction of the cell current in order to eliminate the layers of scale that deposit on the electrode plates. It's usually cheaper to buy the Aquapure 1400 cell kit that comes with the cell, trisensor and power cord vs. buying the parts separately. With the AquaPure 1400, the reading is in grams per liter, which is the same as 1,000 ppm. A member found that the new part fit perfectly with the same mounting holes. Press and release the Temperature button within 5 seconds to enter the salinity calibration screen. Only 17 left in stock - order soon. Not reliable at all and have had problems starting about 1 month after installation. The salt water chlorinator replaces the hassle of having to use granular chlorine. Remove cell for inspection. Please be aware that salt test strips have a large variance in readings (400 - 800 ppm). In this thread, the amperage of the 1400 cell tests at about 5.6 amps, and the amperage of the 700 cell should test at about 2.8 amps.[11]. Add salt to pool, 3.0 gpl to 3.5 gpl. The AquaPure salt-water chlorine sanitizing systems uses salt water to deliver water sanitation by generating chlorine. Must be picked up in our Moorpark, Ca location to qualify for the Jandy limited warranty. If the unit is not correctly installed you may get severe electrical shock or you may fry the system. Note that the center prong is on the cell where the power cord connects to the cell. Check connection. Natural stone can be visually altered over time. Remove and clean flow/temp/salinity sensor contacts. Here is a test you can do to diagnose the trisensor. Ensure there is no loss of pump prime or clogged strainer baskets. The Power Center comes configured for the 1400 cell and the JL1 jumper must be cut if using the 700 cell. 2 for when the cell is installed and 1/2 of the other 2 unions (the "male" 1/2) for creation of the bypass pipe. Unit came with panel knocked out and the circuit board was bad. After 24 hours, verify correct salt reading. Had to replace our original, 14 year old system which developed a front board issue. Avoid using salt with anti-caking agents (sodium ferrocyanide, also known as YPS or yellow prussiate of soda) that could cause some discoloration of fittings and surface finishes in pool. This AquaPure foundation power center pack is designed to se with Zodiac Jandy AquaPure PureLink cell kit. The Jandy AquaPure system consists of a AquaPure Power Center or PureLink Power Centers and either a PURE700 cell or a PURE1400 cell. The Jandy AquaPure salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. It should read 75 F or 24 C. Next, press and hold the board H-Temp test button, and at the same time press the Salinity key (C) together with the Chlorine Production Rate arrow down key (A) on the front cover of the unit. Please try again. All Rights Reserved. ), PURE1400 - 1.25 lb./24 Hr. The remaining bromide will not harm the users, pool equipment or the pool. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. However, the Jandy PLC700 cell kit (for pools up to 12,000 gallons) and the PLC1400 (with a 40,000 gallon capacity) kit contain new cells as well as all the necessary accessories to switch a 2-port setup to the new design.[8]. The AquaPure system is comprised of the following three component parts and an optional pool pump timer. The Jandy AquaPure salt-water chlorine purifying systems use salt water to deliver high-performance water purification with uncompromised performance, reliability and hydraulic efficiency. First thing to check is the cord. While still pressing the test buttons press the Salinity key (C) on the front cover of the unit. We had to replace the filter and pump body! 4.5 out of 5 stars 354 $ 1,098. Jandy no longer supports parts for their older systems. The Jandy AquaPure, PureLink & Nature Fusion Soft Workbook gives a lot of good information on installation and troubleshooting. Thank You. Jandy / Zodiac PLC1400 Replacement Cell Kit for AquaPure / PureLink 1400. Andy tech support makes jokes that I should get it fixed before my pool turns green and yet have not been able to fix the problems nor willing to try. See Section 6.5 of the owner's manual, Winterizing. Adjust total alkalinity to 80-120ppm. No, a pool treated by salt water chlorination is a chlorinated pool in which the chlorine is produced automatically. JANDY AQUAPURE | CONTROL BOX, PURE1400 | R0403000, This product has a 1 year warranty from the manufacturer. See Section 6.3 of the owner's manual Electrolytic Cell Cleaning. It may not display this or other websites correctly. 3.0 to 3.5 gpl of salt is recommended for optimum water conditions. See also, Section 6.4, Flow/Temp/Salinity Sensor Cleaning, Step 4 of the owner's manual. The audible alarm can be permanently disabled by removing the jumper from J2 on the control/power center Power Interface Board (PIB). Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115 / 230 VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. Pool and Spa Parts Depot | Swimming Pool Supplies. Asked on 5/16/2017by Steve. Is it true that salt water chlorination is maintenance free?