city of houston backflow prevention requirements

between one and 5-feet AFF, the assembly must be installed at water service entrance elevation. In the For this reason, all certified backflow prevention assembly testers are responsible for the accuracy of their field-testing and of their Test and Maintenance Reports. Installations must meet Occupational Safety and Health Administration and State of Oregon Occupational Safety and Health codes. Copyright 2021 Hardin & Associates Consulting. Provide fence and gate details (drawings) for all types of . The Cross-Connection Control Subcommittee advises us in this effort. Sump pump discharge piping must meet vault drainage requirements as stated herein. Technical assistance in the area of cross-connection control is offered to public water systems by staff from our central office. 3. A premises-isolation reduced pressure type backflow assembly is required to be installed on all water service connections as listed but not limited to: premises having private wells, water features (swimming pools), geothermal heating & cooling systems, hydronic heating systems, cooling towers, that have access to rivers, lakes, ponds and/or other water sources that can be connected to; are equipped with storage tanks, rainwater-harvesting (excluding those that simply capture rainwater in containers of less than 50 gallons and gravity-feed to landscape), storm-water or groundwater recovery and reuse systems and/or that use, or reuse treated wastewater (grey and/or black-water) on site. In addition, Call 520-791-2650 if you would like more information. All services considered non-potable and do not pose a risk to health. Premises-Isolation assemblies (those that directly protect the public water supply) must be installed on private property at the property line (service connection/point-of-delivery) on the centerline of the city water service, as it runs perpendicular from the right-of-way (R.O.W.). prevent backflow. The City works to protect the water supply by ensuring backflow devices are maintained properly and cross-connection sources are eliminated. For horizontal installations, and for assemblies which are not approved for vertical up installation, the riser must be equipped with a single 90-degree elbow and the assembly is to be no more than the pipe diameter in inches beyond the centerline (or outlet side of the) elbow to accommodate horizontal installations, excepting only the addition of a wye-strainer, flood control shut off valve or other, necessary appurtenance. Licensed BPA testers are also listed in our, TCEQ requires you to have a licensed BPA tester check the BPAwhen it is installed on your irrigation system. An inspection fee must be paid to the Water Bureau prior to replacement of an existing assembly or newly installed assembly on a dedicated fire service. An individual may substitute one year of required experience with: 1 year of College credit (32 Semester Hours) 20 Hours of Approved Training in addition to the required 40-hour Training Course 13. If touch-pad wire must be run underground the wire must be routed through PVC conduit from the meter to the touchpad. Houston, TX 77002. %%EOF Many public water systems also operate rigorous cross-connection control (CCC) programs of their own. For more information on protecting your water, contact the City's Backflow Prevention Inspector at (585) 428-6070 . A Customer Service Inspection Certificate (CSI) is used to document the findings of a Customer Service Inspection. Luckily, this is where it stopped: The worker mixing the pesticide realized the danger and alerted the utility workers, who closed the flush valve before the contamination reached the citys distribution line. The relief-valve must be located 12 above the top of the vault drain opening. Building, transportation, maintenance, and sewer projects. Applications . hbbd``b`A* $XN HqH2} . To protect public health, our Cross-Connection Control (CCC) and Backflow Prevention Program is committed to helping you protect your drinking water system from potential contamination. Ladder orientation must not impede clear access to the assembly and/or vault floor. A Double Check Detector Assembly (DCDA) is typically the type of backflow assembly installed on fire sprinkler water services. You can then select your preferred provider and schedule the service. thermal expansion increases the pressure. General Info (843) 727-7148. state. Cross-Connection Control Program. the system pressure has been increased by A partiallisting of common cross-connection hazards: Individual copies of these publications are free: These manuals are available for purchase from their publishers: For more information, call our main Water Supply Division line, 512-239-4691, and ask for the Cross-Connection Control and Backflow Prevention Program coordinator. K/7tLb"bxOEuY# O>X}xww-[wZ|=m~8Y{&TXcSv>:.8gXq.ih/}^Mz]z>,NwUUC1->`}>TM;]~a^mvoOzm0P9CLN=MMdD,F?oil1jB).1xU]0SM^D7iLbas,=?W_OFZTum LAq0 d$jpwzcZ hdl%P+]/PGjS)EKafdm50jL:9~I^X#R. This list represents companies that have met the requirements and have submitted the proper documentation to register and . The ladder must not encroach on the installation clearances for the type of assembly required. These will allow for necessary clearance for ladders in single assembly installations. Effective September 1, 2017, pursuant to TCEQ Reg-521 "Criminal History Guidelines", those with a felony criminal history should contact TCEQ Licensing Division prior to registering for a training course. The supply side of premises-isolation assemblies must be plumbed with potable water piping and fittings meeting current NSF/ANSI standards for lead content. | Texas Veterans Portal Upon job completion, the provider uploads service details to SwiftQuote, and you can either pay online via credit card or offline directly to the provider. See note below. Note: A Reduced Pressure Detector Assembly (RPDA) is required to be installed where; storage tanks are provided, if the structure is considered a high-rise (requirement stated herein) if supplying marinas, moorages, premises having docks and piers, when rainwater-harvesting, storm-water and/or groundwater recovery and reuse systems are installed and/or that use, or reuse treated wastewater (grey and/or black-water). testers. Official Cross-Connection Control Program forms: Listed below are links to the official TCEQ Cross-Connection Control Program forms. A webcam or HD webcam - built-in, USB plug-in, or: An HD cam or HD camcorder with a video-capture card, Virtual camera software for use with broadcasting software like OBS or IP cameras. RPBA installations must meet all applicable Oregon Administrative Rules, 333-061-0070, Title 21, and Title 28, respectively. In no circumstance may the lower assembly be less than 12 AFF (measured to the lowest point on the assembly) and the higher assembly may not be installed above 5 AFF (measured to the top of the assembly body) unless an OSHA approved permanently mounted platform is installedthat meets the standards as outlined herein. The only thing you pay for is your service booked through the platform. 16. Potential contamination can make extra protection necessary for landscape irrigation systems, spas, swimming pools, solar water heating systems, or even a bucket of soapy water being filled by a garden hose. Otherpublic water systems require the customer tohire alicensed person to conduct the CSI. The bore-sight drain must never be connected to a sewer of any kind, catch basins, sumps, or dry wells. The simplest method to prevent backflow is to have your backflow 23828 30th Ave. S. Enter your requirements and local pros will bid on your service, providing a quote to complete your request. A reduced pressure type assembly must be installed on all water service connections to premises with high-rise buildings (high-rise building: where a building is 75-feet or greater above its lowest finished-floor (slab) elevation to top of structure). Vault lids with hinged frame and covers (Oldcastle Infrastructure or equivalent): where applicable use Center-Offset frame and cover lids (Oldcastle Infrastructure or equivalent). If your property or business type is not included in the above list and you have a specific question about your legal requirements, please call 311 to have your inquiry directed to DEP. Yes! The water riser/supply pipe must be installed 12 from the foundation frontage wall to centerline of pipe on the centerline of the city water service as it runs perpendicular from the R.O.W. By continuing to use this website, you consent to the use of cookies in accordance with our Cookie Policy. regarding the abilities, performance or quality of service of the This solution is free, but not highly reliable. An individual may substitute one year of required experience with: 1 year of College credit (32 Semester Hours), 20 Hours of Approved Training in addition to the required 40-hour Training Course. Can you always be this careful? You can find one from our, If you install your own system, have a licensed BPA tester confirm that the BPA is installed and operating properly. Assemblies 2 and smaller may have reduced clearances as approved by the Water Quality Inspector. On this page: How Cross-Connection and Backflow Can Lead to Contaminated Water Definitions Your public water system must require a CSI to be performedunder the following circumstances: Water providers notify their customers that a CSI is required. . All wiring from the touchpad to the bypass meter must be insulated 1 pair solid 22 AWG copper wires secured so as not to interfere with the operation and maintenance of the backflow assembly. 7. Under normal operation water flows from the City of Houston waterlines to the water customers. A RPBA must be installed on domestic water services to mixed-use and multi-tenant premises. The City of Hamilton began a 'Backflow Prevention Program' to protect your drinking water quality by making sure that the appropriate backflow prevention devices had been installed and inspected on private properties in the Hamilton area. Maintenance requirements include regular testing based on the type of device being used. The relief-valve must be located 12 above finished slab elevation. A minimum of a Double Check Valve Assembly (DCVA) for premises-isolation must be installed on water services: If the water meter is 2-inches or larger. Water and pesticides flowed from the pesticide tank back through the hose and into the water lines of the residence. accept any responsibilities for the actions or performance of such . An approved rigidly mounted ladder, with an extension which extends 3 above the vault lid (Oldcastle Infrastructure Pull-Up Extension, Bilco LU-1 or equivalent) is required if the vault or chamber is 4 or greater in depth. All splices must be accessible. The community of Houston is nestled in the beautiful Bulkley Valley amongst some of BC's finest outdoor recreational opportunities. Strategically located halfway between the hub cities of Prince George and Terrace, Houston is home to the outdoor enthusiast.. With a population of 3200 people, there is always room on the riverbank, lake or the many walking and hiking trails in the area. 3. customer whenever a service 12. 15. The Portland Water Bureau will determine the degree of risk. 5. 18. @rvk`1i)S8::Al0T h``XS~W23TV9lU4v Completing this course also provides continuing education credit for the following licenses: 32-hours of continuing education credits for licensed Backflow Prevention Assembly Testers, 12-hours of continuing education credits for licensed Water and Wastewater Operators, 12-hours of continuing education credits for licensed Landscape Irrigators (LI), 12-hours of continuing education credits for licensed Customer Service Inspectors (CSI), 12-hours of continuing education credits for licensed Water Treatment Specialist, 100-hours of training credit to an applicant for a Plumbing Inspectors license (through TSBPE). City of Houston - Backflow Assembly & Test Report Form. State rules and City Codes require you to: Backflow Assembly Installation Requirements. A moisture-proof light fixture will be required if adequate lighting is not available. Fax the completed Plumbing Permit Application (CE-1020) to the Permits Office at 832-395-9621. mandate a series of measures and backflow prevention devices to Items can be submitted to our office . most obvious case, a toilet flush cistern and its water supply must Effective against backpressure backflow and back-siphonage and may be used to isolate . The following individuals are authorized to perform CSIs: OurOccupational Licensing Sectionlicenses Customer Service Inspectors and maintains a database of licensed Customer Service Inspectors. An alternate assembly location may only be considered for retrofit applications and excludes new construction. Vertical, physical separation between the end of a water supply outlet and the flood-level rim of a receiving vessel. 8. Advance Pay Account holders may apply for the permit by fax. The RPDA must be installed at the service connection/point-of-delivery to the premises as outlined herein and as defined by OAR Chapter 333-061-0020. What is backflow? assembly tested on an annual basis. For your convenience we provide a list of State Certified Backflow Assembly Testers in our area. Copyright 2023 Houston Public Works. All Rights Reserved. Email my test form to: backflow.utilities@sarasotafl.gov . A sump pump will be required if vaults are unable to be kept free of standing water. i. FAX: 206-824-0806 If water service enters a building from below grade (slab-on-grade) or at an elevation less than 1-foot above finished floor (AFF), the assembly is to be raised to a minimum of1-foot AFF (measured to the lowest part of the assembly). ?H!H2@5H0 -.l>@Lu ut&30 c The assemblies are to be installed no more than the pipe diameter in inches from the outlet side of the elbows off the Tee. Backflow assemblies installed on water services for fire use only; must be installed on private property at the property line (service connection/point-of-delivery as defined in the OAR) on the centerline of the city water service as it runs perpendicular from the R.O.W. 751 0 obj <> endobj Installations must be inspected by a Water Bureau Water Quality Inspector and will require that a Backflow Inspection Fee be paid. All vaults and enclosures for backflow assemblies must be kept free of any debris and/or objects that interfere with these installation requirements and those applicable to OAR 333-061-0071. 9. The bore-sight drain must be in a level horizontal orientation and must be screened off at both ends and not have a lay length of greater than 20-feet. Be aware these forms must be submitted to the responsible water system for recordkeeping purposes. 3) Annual registration fee of $100.00. Installation Inspection Request endstream endobj 176 0 obj <> endobj 177 0 obj <>/ProcSet[/PDF/Text/ImageB]/XObject<>>>/Rotate 0/Type/Page>> endobj 178 0 obj <>stream 3907 South Industrial Drive A RPBA is required where the water is treated in any way. Touchpads not installed in vault doors or on a building face must be installed using the Brooks #37, 12 X 20 box w/T&R lid. 1750 12 th Street Sarasota, Florida 34236. Splices must be made with 3M Scotchlok moisture resistant connectors, part number UR or UY or equivalent. By replacing pipes before they break, taking steps to ensure that system pressures do not fall during periods of high demand, and asking for the cooperation of customers when there is a risk that system pressures could fall below safe levels, your public water system operator reduces the risk of backflow. Your water systems role begins with good system maintenance and sound operations. In the case of parallel Reduced pressure assemblies the lower of the two will need to extend beyond the 4 minimum clearance behind to accommodate a drain assembly for relief valve orifice of the assembly above. is booked, canceled, or The drain must never be less than 12 above the flood elevation of a water source, swale or any other catchment subject to overflow/flooding. All exposed piping inside enclosures must be insulated with commercially manufactured closed-cell pipe insulation or a heat source must be provided. Where the touch-pad wire follows the path of other electrical wiring, shielded wire as described above must be used. Suite 100 A RPBA must always be installed 12 above finished grade or the 100-year flood-plain, whichever is greater and meet all applicable drainage requirements stated herein. If suspended from ceilings, pipe hangers designed to carry the full load of the assembly must be installed. Back pressure is the result of a higher pressure in the system The airgap must be at least twice the inside diameter of the relief-valve, measured vertically above the top of any drain or receiving vessel. forcing it into a clogged gutter, downspout, or sewer pipe to flush out the clog, connecting it directly to a hose-end sprayer to apply pesticide or fertilizer to your yard, connecting it to a soap-and-brush attachment to wash your car, boat, or siding, letting the end of the hose lie in a puddle or pool of water on the ground. Prior to installing a backflow assembly within a building or structure, accurate drawings must be submitted to Portland Water Bureau Water Quality Inspection group for approval. HVK%')dVe%X[oLWR=I Dtrtq3,Vg(&_[N?YG5P[IYH^h\z=d+k,IU%TgrtM%gNYc8-@OiGW.ili\B,|g6 ,~=z. 1. Touchpads must be compatible with these meters. Under normal operation water flows from the City of Houston waterlines to the water customers. The air-gap must never be less than 1. hb``a``d`c`Lcb@ !FV&m3@(Z R pGAsD / 6/`9ARTkX[Turd_0 ' Premises-Isolation Reduced Pressure Backflow Assembly (RPBA) installations requirements. For the safety of its public water supply, the City diligently ensures that homes and businesses are in compliance with cross-connection/backflow requirements. Backflow occurs due to a sudden change in pressure or a break in the water main. Each of these common uses of a garden hose sets up a cross connection: No doubt you can think of other examples. All premises having more than one domestic water service. Technical information about how and where to install backflow prevention assemblies. Please note that these forms are periodically updated so, for the most up to date version of the forms, please use the links on this page. hb```5|@CTBI$NV7000jlHM. The simplest method to prevent backflow is to have your backflow assembly tested on an annual basis. 8. Backflow Prevention Assembly Test and Maintenance Report(, Customer Service Inspections: A Guide for Public Water Systems (TCEQ publication, Backflow Protection on Fire Prevention Systems (TCEQ publication, A Public Water System Guide to Preparing a Backflow-Incident Emergency-Response Plan (TCEQ publication, A Public Water System Guide to Responding to a Backflow Incident (TCEQ publication, Establishing and Managing an Effective Cross-Connection Control Program (TCEQ publication.

Barn Homes For Sale In Arkansas, Eyecare Partners Check, Articles C

city of houston backflow prevention requirements